Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74.654
Filtrar
1.
Hipertens. riesgo vasc ; 41(2): 104-117, abr.-jun2024. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-232396

RESUMO

La hipertensión arterial (HTA) se ha convertido en un factor de riesgo central para el desarrollo de enfermedades cardiovasculares (CV), lo que subraya la importancia de su diagnóstico preciso. Numerosos estudios han establecido una estrecha relación entre los valores elevados de la presión arterial sistólica (PAS) y diastólica (PAD) y un incremento en el riesgo de padecer algún evento cardiovascular (ECV). Tradicionalmente, las mediciones de la presión arterial (PA) realizadas en entornos clínicos han sido el principal método para diagnosticar y evaluar la HTA. No obstante, en los últimos años, se ha reconocido que las mediciones de la PA obtenidas fuera del ambiente clínico, mediante la automedida de la presión arterial (AMPA) y la monitorización ambulatoria de la presión arterial (MAPA), ofrecen una perspectiva más realista de la vida cotidiana de los pacientes y, por lo tanto, brindan resultados más fiables. Dada la evolución de los dispositivos médicos, los criterios diagnósticos y la creciente relevancia de componentes de la MAPA en la predicción de ECV, se requiere una actualización integral que sea práctica para la clínica. Esta revisión tiene como objetivo proporcionar una actualización de la MAPA, enfocándose en su importancia en la evaluación de la HTA. Además, se analizarán los umbrales diagnósticos, los distintos fenotipos según el ciclo circadiano y las recomendaciones en diferentes poblaciones, asimismo, se ofrecerán sugerencias concretas para la implementación efectiva de la MAPA en la práctica clínica, lo que permitirá a los profesionales de la salud tomar decisiones fundamentadas y mejorar la atención de sus pacientes.(AU)


Hypertension has become a central risk factor for the development of cardiovascular disease, underscoring the importance of its accurate diagnosis. Numerous studies have established a close relationship between elevated systolic (SBP) and diastolic (DBP) blood pressure and an increased risk of cardiovascular event (CVE). Traditionally, blood pressure (BP) measurements performed in clinical settings have been the main method for diagnosing and assessing hypertension. However, in recent years, it has been recognized that BP measurements obtained outside the clinical setting, using self-monitoring blood pressure (SMBP) and ambulatory blood pressure monitoring (ABPM), offer a more realistic perspective of patients’ daily lives and therefore provide more reliable results. Given the evolution of medical devices, diagnostic criteria, and the increasing relevance of certain components of ABPM in the prediction of adverse cardiovascular outcomes, a comprehensive update that is practical for daily clinical practice is required. The main objective of this article is to provide an updated review of ABPM, focusing on its importance in the evaluation of hypertension and its impact on public health in Colombia. In addition, it will discuss the implications of changes in diagnostic thresholds and provide concrete recommendations for the effective implementation of ABPM in clinical practice, allowing health professionals to make informed decisions and improve the care of their patients.(AU)


Assuntos
Humanos , Masculino , Feminino , Pressão Arterial , Monitorização Ambulatorial da Pressão Arterial , Doenças Cardiovasculares/prevenção & controle , Fatores de Risco , Pressão Sanguínea
2.
Cureus ; 16(2): e55206, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38558648

RESUMO

Introduction Pulmonary hypertension (PH) is a recognized complication in patients with end-stage renal disease (ESRD undergoing maintenance hemodialysis (MHD). PH is commonly found in patients with chronic kidney disease (CKD) and ESRD. PH is associated with increased morbidity and mortality in patients with CKD. Methodology This cross-sectional study aimed to assess the prevalence of PH and its associated risk factors in MHD patients. A total of 220 ESRD patients on MHD patients at The Kidney Center, Karachi, Pakistan, aged 18-70 were included. Patients with chronic obstructive lung disease, valvular heart disease, and obstructive sleep apnea were excluded, as these conditions can be responsible for PH. PH was evaluated by echocardiography (ECHO), which was performed by a cardiologist. Results The mean age was 50.65 ± 14.4 years, with 131 (59.5%) males and 89 (40.5%) females. The average duration on hemodialysis was 5.3 ± 2.8 years. Hypertension (89.5%) and ischemic heart disease (24.1%) were prominent comorbidities. Hypertensive nephropathy (42.7%) was the leading cause of ESRD. Left ventricular hypertrophy was mild in most cases (85.5%), whereas regional wall motion abnormality (RWMA) was common (67.3%). The average pulmonary artery pressure was 35.2 ± 15.3 mmHg. Out of 220 patients, 109 patients (49.8%) of them had mild PH, nine patients (4.1%) had severe PH, and 72 patients (32.7%) had moderate PH. Associations between PH and various factors were examined. RWMA, left ventricular hypertrophy, and left ventricular ejection fraction were significantly associated with PH (p < 0.001). Serum calcium and albumin levels were also associated with PH severity (p < 0.05). Other demographic and laboratory parameters did not show a significant association. Conclusion This study highlights the prevalence of PH in MHD patients and identifies associated risk factors. Understanding these associations can aid in better managing PH in ESRD patients.

3.
Cureus ; 16(2): e55224, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38558663

RESUMO

Introduction Prolonged sitting-induced blood pooling in the lower legs can increase blood pressure through increased sympathetic nerve activity and peripheral vascular resistance, an aspect that has been understudied as a primary outcome. This study compared the effects of prolonged sitting with those of prolonged supination on blood pressure in healthy young men. Methods This randomized crossover study included 16 healthy young men (mean age: 21.6 ± 0.7 years) who were randomly assigned to a three-hour supine (CON) or three-hour sitting (SIT) condition, followed by a washout period of at least one week. Systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), heart rate (HR), low-frequency/high-frequency (LF/HF) ratio derived from heart rate variability, and leg circumference were measured at 60, 120, and 180 minutes from baseline. These indices were compared by two-way (time × conditions) analysis of variance (ANOVA). Results In the SIT condition, DBP, MAP, HR, LF/HF ratio, and leg circumference increased significantly over time (P < 0.05) and were significantly higher than those in the CON condition (P < 0.05). However, SBP showed no significant change over time and between conditions. Conclusions The findings indicate the involvement of sympathetic nerve activity and increased peripheral vascular resistance induced by fluid retention in the lower legs with increased DBP and MAP in healthy young men.

4.
Cureus ; 16(2): e55239, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38558696

RESUMO

Normal pressure hydrocephalus (NPH) is characterized by pathologic ventriculomegaly with normal opening pressures on lumbar puncture. It commonly presents with a triad of gait disturbance, cognitive impairment, and urinary bladder detrusor dysfunction. Its pathogenesis is complex but is thought to arise in the setting of imbalanced cerebrospinal fluid (CSF) secretion and absorption. Given that intracranial pressure often remains normal in the setting of NPH, visual symptoms are quite uncommon. Here we present a case of a 70-year-old female with a subacute history of visual aberration described as a seconds-long persistent recurrence of visual images after the stimulus was removed from the visual field in the setting of slowed and unstable gait, urinary urgency, and cognitive impairment. This patient was evaluated and ultimately diagnosed with NPH before undergoing definitive treatment with ventriculoperitoneal shunt implantation. She has shown persistent responsiveness to shunting of the CSF as manifested by sustained improvement in gait speed and stability, urinary bladder urgency, and palinopsia resolution at the six-month follow-up assessment.

5.
Front Aging Neurosci ; 16: 1362637, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38560023

RESUMO

Background: Disproportionately enlarged subarachnoid-space hydrocephalus (DESH) is a key feature for Hakim disease (idiopathic normal pressure hydrocephalus: iNPH), but subjectively evaluated. To develop automatic quantitative assessment of DESH with automatic segmentation using combined deep learning models. Methods: This study included 180 participants (42 Hakim patients, 138 healthy volunteers; 78 males, 102 females). Overall, 159 three-dimensional (3D) T1-weighted and 180 T2-weighted MRIs were included. As a semantic segmentation, 3D MRIs were automatically segmented in the total ventricles, total subarachnoid space (SAS), high-convexity SAS, and Sylvian fissure and basal cistern on the 3D U-Net model. As an image classification, DESH, ventricular dilatation (VD), tightened sulci in the high convexities (THC), and Sylvian fissure dilatation (SFD) were automatically assessed on the multimodal convolutional neural network (CNN) model. For both deep learning models, 110 T1- and 130 T2-weighted MRIs were used for training, 30 T1- and 30 T2-weighted MRIs for internal validation, and the remaining 19 T1- and 20 T2-weighted MRIs for external validation. Dice score was calculated as (overlapping area) × 2/total area. Results: Automatic region extraction from 3D T1- and T2-weighted MRI was accurate for the total ventricles (mean Dice scores: 0.85 and 0.83), Sylvian fissure and basal cistern (0.70 and 0.69), and high-convexity SAS (0.68 and 0.60), respectively. Automatic determination of DESH, VD, THC, and SFD from the segmented regions on the multimodal CNN model was sufficiently reliable; all of the mean softmax probability scores were exceeded by 0.95. All of the areas under the receiver-operating characteristic curves of the DESH, Venthi, and Sylhi indexes calculated by the segmented regions for detecting DESH were exceeded by 0.97. Conclusion: Using 3D U-Net and a multimodal CNN, DESH was automatically detected with automatically segmented regions from 3D MRIs. Our developed diagnostic support tool can improve the precision of Hakim disease (iNPH) diagnosis.

6.
Brain Spine ; 4: 102771, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38560043

RESUMO

Introduction: Positional changes in intracranial pressure (ICP) have been described in humans when measured over minutes or hours in a static posture, with ICP higher when lying supine than when sitting or standing upright. However, humans are often ambulant with frequent changes in position self-generated by active movement. Research question: We explored how ICP changes during movement between body positions. Material and methods: Sixty-two patients undergoing clinical ICP monitoring were recruited. Patients were relatively well, ambulatory and of mixed age, body habitus and pathology. We instructed patients to move back and forth between sitting and standing or lying and sitting positions at 20 s intervals after an initial 60s at rest. We simultaneously measured body position kinematics from inertial measurement units and ICP from an intraparenchymal probe at 100 Hz. Results: ICP increased transiently during movements beyond the level expected by body position alone. The amplitude of the increase varied between participants but was on average ∼5 mmHg during sit-to-stand, stand-to-sit and sit-to-lie movements and 10.8 mmHg [95%CI: 9.3,12.4] during lie-to-sit movements. The amplitude increased slightly with age, was greater in males, and increased with median 24-h ICP. For lie-to-sit and sit-to-lie movements, higher BMI was associated with greater mid-movement increase (ß = 0.99 [0.78,1.20]; ß = 0.49 [0.34,0.64], respectively). Discussion and conclusion: ICP increases during movement between body positions. The amplitude of the increase in ICP varies with type of movement, age, sex, and BMI. This could be a marker of disturbed ICP dynamics and may be particularly relevant for patients with CSF-diverting shunts in situ.

7.
Neurotrauma Rep ; 5(1): 293-303, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38560491

RESUMO

There are proponents of decompressive craniectomy (DC) and its various modifications who claim reasonable clinical outcomes for each of them. Clinical outcome in cases of traumatic brain injury, managed conservatively or aided by different surgical techniques, depends on multiple factors, which vary widely among patients and have complex interplay, making it difficult to compare one case with another in absolute terms. This forms the basis of the perceived necessity to have a standard model to study, compare, and strategize in this field. We designed a phantom-based model and present the findings of the study aimed at establishing a correlation of the volume of intracranial space and changes in intracranial pressure (ICP) with surface area of the craniectomy defect created during DC and brain herniation volume. A roughly hemispherical radio-opaque container was scanned on a 128-slice computed tomography scanner. Craniectomies of different sizes and shapes were marked on the walls of the phantom. Two spherical sacs of stretchable materials were subsequently placed inside the phantom, fixed to three-way connectors, filled with water, and connected with transducers. The terminals of the transducer cables were coupled with the display monitor through a signal amplifier and processor module. Parts of the wall of the phantom were removed to let portions of the sac herniate through the defect, simulating a DC. Volume measurements using AW volume share 7® software were done. Resection of a 12.7 × 11.5 cm part of the wall resulted in a 10-cm-diameter defect in the wall. Volume differential of 35 mL created a midline shift of 5 mm to the side with lesser volume. When measuring pressure in two stretchable sacs contained inside the phantom, there always remained a pressure differential ranging from 1 to 2 mm Hg in different recordings, even with sacs on both sides containing an equal volume of fluids. Creating a circular wall defect of 10 cm in diameter with an intracavitary pressure of 35 mm Hg on the ipsilateral sac and 33 mm on the contralateral sac recorded with intact walls, resulted in a true volume expansion of 48.411 cm3. The herniation resulted in a reduction of pressure in both sacs, with the pressure recorded as 25 mm in the ipsilateral sac and 24 mm in the contralateral sac. The findings closely matched those of the other model-based studies. Refinement of the materials used is likely to provide a valid platform to study cranial volume, ICP, craniectomy size, and brain prolapse volume in real time. The model will help in pre-operatively choosing the most appropriate technique between a classical DC, a hinge craniotomy, and an expansive cranioplasty technique in cases of refractory raised ICP.

8.
J Biomed Opt ; 29(3): 037003, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38560532

RESUMO

Significance: Glaucoma, a leading cause of global blindness, disproportionately affects low-income regions due to expensive diagnostic methods. Affordable intraocular pressure (IOP) measurement is crucial for early detection, especially in low- and middle-income countries. Aim: We developed a remote photonic IOP biomonitoring method by deep learning of the speckle patterns reflected from an eye sclera stimulated by a sound source. We aimed to achieve precise IOP measurements. Approach: IOP was artificially raised in 24 pig eyeballs, considered similar to human eyes, to apply our biomonitoring method. By deep learning of the speckle pattern videos, we analyzed the data for accurate IOP determination. Results: Our method demonstrated the possibility of high-precision IOP measurements. Deep learning effectively analyzed the speckle patterns, enabling accurate IOP determination, with the potential for global use. Conclusions: The novel, affordable, and accurate remote photonic IOP biomonitoring method for glaucoma diagnosis, tested on pig eyes, shows promising results. Leveraging deep learning and speckle pattern analysis, together with the development of a prototype for human eyes testing, could enhance diagnosis and management, particularly in resource-constrained settings worldwide.


Assuntos
Aprendizado Profundo , Glaucoma , Humanos , Animais , Suínos , Pressão Intraocular , Glaucoma/diagnóstico por imagem , Tonometria Ocular , Esclera
9.
Bioscience ; 74(3): 159-168, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38560619

RESUMO

Remote sensing data are important for assessing ecological change, but their value is often restricted by their limited temporal coverage. Major historical events that affected the environment, such as those associated with colonial history, World War II, or the Green Revolution are not captured by modern remote sensing. In the present article, we highlight the potential of globally available black-and-white satellite photographs to expand ecological and conservation assessments back to the 1960s and to illuminate ecological concepts such as shifting baselines, time-lag responses, and legacy effects. This historical satellite photography can be used to monitor ecosystem extent and structure, species' populations and habitats, and human pressures on the environment. Even though the data were declassified decades ago, their use in ecology and conservation remains limited. But recent advances in image processing and analysis can now unlock this research resource. We encourage the use of this opportunity to address important ecological and conservation questions.

10.
Heliyon ; 10(6): e28114, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38560666

RESUMO

Objectives: To investigate the associations of motor capacity of the lower extremity and mobility performance in daily physical activities with peak foot plantar pressures during walking among older women. Methods: Using the data collected among 58 community-dwelling older women (68.66 ± 3.85 years), Pearson correlation and multiple linear regression analyses were performed to analyze the associations of motor capacity of the lower extremity (the 30-s chair stand test, the timed one-leg stance with eyes closed, and the Fugl-Meyer assessment of lower extremity), mobility performance in daily physical activities (the average minutes of moderate to vigorous physical activity every day and the metabolic equivalents), and foot plantar pressures (peak force and peak pressure) with the age and body fat percentage as covariates. Results: (1) The motor capacity of the lower extremity has higher explanatory power for peak foot plantar pressures compared with the mobility performance in daily physical activities. (2) Higher body fat percentage was positively associated with peak force and pressure, while a lower score on the Fugl-Meyer assessment of lower extremity was negatively associated with both of them. (3) The metabolic equivalents were positively associated with the peak force, while the 30-s chair stand test was negatively associated with it. Conclusions: Mobility performance in daily physical activities can be significant predictors for peak foot plantar pressures among older women. The significant predictor variables include the Fugl-Meyer assessment of lower extremity, the 30-s chair stand test, and metabolic equivalents.

11.
ADMET DMPK ; 12(1): 167-176, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38560714

RESUMO

Background and purpose: Doxazosin mesylate (DOX) is an antihypertensive drug that possesses poor water solubility and, hence, poor release properties. Both nanosuspensions and self-nanoemulsifying drug delivery systems (SNEDDS) are becoming nanotechnology techniques for the enhancement of water solubility of different drugs. Experimental approach: The study's goal was to identify the best drug delivery system able to enhance the release and antihypertensive effect of DOX by comparing the physical characteristics such as particle size, zeta potential, entrapment efficiency, release rate, and main arterial blood pressure of DOX-loaded nanosuspensions and SNEDDS in liquid and solid form. Key results: DOX nanosuspension preparation had a particle size of 385±13 nm, poly-dispersity index of 0.049±3, zeta potential of 50 ± 4 mV and drug release after 20 min (91±0.43 %). Liquid SNEDDS had a droplet size of 224±15 nm, poly-dispersity index of (0.470±0.01), zeta potential of -5±0.10 mV and DR20min of 93±4 %. Solid SEDDS showed particle size of 79±14 nm, poly-dispersity index of 1±0.00, a zeta potential of -18 ±0.26 mv and DR20min of 100 ±2.72 %. Conclusion: Finally, in terms of the mean arterial blood pressure lowering, solid SNEDDS performed better effect than both liquid SNEDDS and nanosuspension (P >0.05).

12.
Front Pediatr ; 12: 1367710, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38562138

RESUMO

Background: Asthma is a common chronic respiratory disease in children. Alongside pharmacological interventions, inspiratory muscle training (IMT) emerges as a complementary therapeutic approach for asthma management. However, the extent of its efficacy in pediatric populations remains uncertain when compared to its benefits in adults. This systematic review aims to evaluate the effectiveness of IMT with threshold loading in children with asthma. Methods: Randomized controlled trials (RCTs) evaluating the efficacy of inspiratory muscle training in pediatric asthma patients were identified through June 2023 across various literature databases, including PubMed, Embase, Cochrane Central Register of Controlled Trials (CENTRAL), Cumulative Index to Nursing and Allied Health Literature (CINAL), Web of Science, China Knowledge Resource Integrated Database (CNKI), Wei Pu Database, Wan Fang Database, and Chinese Biomedical Database (CBM). These trials compared inspiratory muscle training against sham inspiratory muscle training and conventional care. Eligible studies were assessed in terms of risk of bias and quality of evidence. Where feasible, data were pooled and subjected to meta-analysis, with results reported as mean differences (MDs) and 95% confidence intervals (CIs). Results: Six trials involving 333 patients were included in the analysis. IMT demonstrated significant improvements in maximum inspiratory pressure (MIP) (MD 25.36, 95% CI 2.47-48.26, P = 0.03), maximum expiratory pressure (MEP) (MD 14.72, 95% CI 4.21-25.24, P = 0.006), forced vital capacity in percent predicted values [FVC(% pred)] (MD 3.90, 95% CI 1.86-5.93, P = 0.0002), forced expiratory volume in the first second in percent predicted values [FEV1(% pred)] (MD 4.96, 95% CI 2.60-7.32, P < 0.0001), ratio of forced expiratory volume in 1 s to forced vital capacity (FEV1/FVC) (MD 4.94, 95% CI 2.66-7.21, P < 0.0001), and asthma control test (ACT) (MD = 1.86, 95% CI: 0.96-2.75, P < 0.0001). Conclusions: Findings from randomized controlled trials indicate that inspiratory muscle training enhances respiratory muscle strength and pulmonary function in pediatric asthma patients. Systematic Review Registration: www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42023449918, identifier: CRD42023449918.

13.
J Phys Ther Sci ; 36(4): 175-180, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562537

RESUMO

[Purpose] The incidence of floating toes in children is increasing. Although the anteroposterior center of pressure in children is present posteriorly, its relationship with the floating toe is unclear. This study aimed to clarify the relationship between the position of the anteroposterior center of pressure and the floating toe in an upright posture in children. [Participants and Methods] In this cross-sectional study, a Win-Pod (Medicapteurs) platform was used to measure the position of the anteroposterior center of pressure in 208 boys and 195 girls from Japanese elementary schools. Using images of the plantar footprint, floating toes were assessed and the floating toe score was calculated. [Results] The anteroposterior center of pressure position was situated 32.3 ± 8.2% from the heel. The floating toe score of all the participants was 3.5 ± 2.4, with a very high rate of 98%. The floating toe score had a significant, moderate correlation with age, height, weight, and the anteroposterior center-of-pressure position. Multivariate analysis revealed an association between the floating toe score and the anteroposterior center-of-pressure position, height, and weight. [Conclusion] There is significant relationship between the anteroposterior center-of-pressure position and the floating toe score in an upright posture in Japanese elementary school students.

14.
Int J Public Health ; 69: 1606766, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38562553

RESUMO

Objective: The objective of the study was to determine the prevalence and determinants of ever-measured blood pressure, prehypertension, and raised blood pressure at national, state and district levels in India. Methods: We analysed data from the National Family Health Survey (NFHS-5), on 743,067 adults aged 18-54 years. The sample consisted of 87.6% females and 12.4% males. We estimated prevalence rates and determined adjusted odds ratios for various dependent variables related to blood pressure. Geographical variations were visualized on the map of India, and multivariate logistic regression was employed at state and district levels, with significance set at p < 0.05. Results: The prevalence of ever-measured blood pressure varied widely, from 30.3% to 98.5% across districts, with southern and northern regions showing higher rates. Prehypertension affected 33.7% of the population, with varying prevalence across districts. Raised blood pressure was there in 15.9%, with notably higher rates in southern region (16.8%). Determinants included age, gender, education, wealth, lifestyle, obesity, and blood glucose levels. Conclusion: These findings demonstrate the subnational variations in blood pressure, can guide evidence-based interventions at the state and district level, towards reducing the burden of raised blood pressure and enhancing overall population health.


Assuntos
Hipertensão , Pré-Hipertensão , Adulto , Masculino , Feminino , Humanos , Pré-Hipertensão/epidemiologia , Pressão Sanguínea , Fatores de Risco , Obesidade , Inquéritos Epidemiológicos , Índia/epidemiologia , Prevalência , Hipertensão/epidemiologia
15.
Front Bioeng Biotechnol ; 12: 1352490, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38562668

RESUMO

Shunt surgery is the main treatment modality for hydrocephalus, the leading cause of brain surgery in children. The efficacy of shunt surgery, particularly in infant hydrocephalus, continues to present serious challenges in achieving improved outcomes. The crucial role of correct adjustments of valve performance levels in shunt outcomes has been underscored. However, there are discrepancies in the performance levels of valves from different companies. This study aims to address this concern by optimizing both the number and range of valve performance levels for infant hydrocephalus, aiming for improved shunt surgery outcomes. We conducted a single-center cohort study encompassing infant hydrocephalus cases that underwent initial shunt surgery without subsequent failure or unimproved outcomes. An unsupervised hierarchical machine learning method was utilized for clustering and reporting the valve drainage pressure values for all patients within each identified cluster. The optimal number of clusters corresponds to the number of valve performance levels, with the valve drainage pressure ranges within each cluster indicating the pressure range for each performance level. Comparisons based on the Silhouette coefficient between 3-7 clusters revealed that this coefficient for the 4-cluster (4-performance level) was at least 28.3% higher than that of other cluster formations in terms of intra-cluster similarity. The Davies-Bouldin index for the 4-performance level was at least 37.2% lower than that of other configurations in terms of inter-cluster dissimilarity. Cluster stability, indicated by a Jaccard index of 71% for the 4-performance level valve, validated the robustness, reliability, and repeatability of our findings. Our suggested optimized drainage pressure ranges for each performance level (1.5-5.0, 5.0-9.0, 9.0-15.0, and 15.0-18.0 cm H2O) may potentially assist neurosurgeons in improving clinical outcomes for patients with shunted infantile hydrocephalus.

16.
Mar Pollut Bull ; 202: 116275, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38564821

RESUMO

Mesopelagic water from the deep Eastern Mediterranean Sea (EMS) was collected under disrupted (REPRESS) or undisturbed (HP) pressure conditions and was acclimated to oil (OIL) or dispersed-oil (DISPOIL) under in situ pressure and temperature (10 MPa, 14 °C). Decompression resulted in oil-acclimatised microbial communities of lower diversity despite the restoration of in situ pressure conditions during the 1-week incubation. Further biodiversity loss was observed when oil-acclimatised communities were transferred to ONR7 medium to facilitate the isolation of oil-degrading bacteria. Microbial diversity loss impacted the degradation of recalcitrant oil compounds, especially PAHs, as low-abundance taxa, linked with PAH degradation, were outcompeted in the enrichment process. Thalassomonas, Pseudoalteromonas, Halomonas and Alcanivorax were enriched in ONR7 under all experimental conditions. No effect of dispersant application on the microbial community structure was identified. A. venustensis was isolated under all tested conditions suggesting a potential key role of this species in hydrocarbons removal in the deep EMS.

17.
Physiol Meas ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565129

RESUMO

OBJECTIVES: In this study, we test the hypothesis that if, as demonstrated in a previous study, brachial arteries exhibit hysteresis as the occluding cuff is deflated and fail to open until cuff pressure (CP) is well below true intra-arterial blood pressure (IAPB), estimating systolic (SBP) and diastolic blood pressure (DBP) from the presence of Korotkoff sounds as CP increases may eliminate these errors and give more accurate estimates of SBP and DBP relative to IABP readings. Approach. In 62 subjects of varying ages (45.1±19.8, range 20-6 - 75.8 years), including 44 men (45.3±19.4, range 20.6 - 75.8 years) and 18 women (44.4±21.4, range 20.9 - 75.3 years), we sequentially recorded SBP and DBP both during cuff inflation and cuff deflation using Korotkoff sounds. Results. There was a significant (p<0.0001) increase in SBP from 122.8±13.2 to 127.6±13.0 mmHg and a significant (p=0.0001) increase in DBP from 70.0±9.0 to 77.5±9.7 mmHg. Of the 62 subjects, 51 showed a positive increase in SBP (0 to 14 mmHg) and 11 subjects showed a reduction (-0.3 to -7 mmHg). The average differences for SBP and DBP estimates derived as the cuff inflates and those derived as the cuff deflates were 4.8±4.6 mmHg and 2.5±4.6mmHg, not dissimilar to the differences reported between IABP and NIBP measurements. Although we could not develop multiparameter linear or non-linear models to explain this phenomenon we have clearly demonstrated through ANOVA tests that both body mass index (BMI) and pulse wave velocity (PWV) are implicated, supporting the hypothesis that the phenomenon is associated with age, higher BMI and stiffer arteries. Significance. The implications of this study are that brachial sphygmomanometry carried out during cuff inflation could be more accurate than measurements carried out as the cuff deflates. Further research is required to validate these results with intra-arterial blood pressure measurements. .

18.
Artigo em Inglês | MEDLINE | ID: mdl-38565717

RESUMO

PURPOSE: In arterial disease, the presence of two or more serial stenotic lesions is common. For mild lesions, it is difficult to predict whether their combined effect is hemodynamically significant. This study assessed the hemodynamic significance of idealized serial stenotic lesions by simulating their hemodynamic interaction in a computational flow model. MATERIALS AND METHODS: Flow was simulated with SimVascular software in 34 serial lesions, using moderate (15 mL/s) and high (30 mL/s) flow rates. Combinations of one concentric and two eccentric lesions, all 50% area reduction, were designed with variations in interstenotic distance and in relative direction of eccentricity. Fluid and fluid-structure simulations were performed to quantify the combined pressure gradient. RESULTS: At a moderate flow rate, the combined pressure gradient of two lesions ranged from 3.8 to 7.7 mmHg, which increased to a range of 12.5-24.3 mmHg for a high flow rate. Eccentricity caused an up to two-fold increase in pressure gradient relative to concentric lesions. At a high flow rate, the combined pressure gradient for serial eccentric lesions often exceeded the sum of the individual lesions. The relative direction of eccentricity altered the pressure gradient by 15-25%. The impact of flow pulsatility and wall deformability was minor. CONCLUSION: This flow simulation study revealed that lesion eccentricity is an adverse factor in the hemodynamic significance of isolated stenotic lesions and in serial stenotic lesions. Two 50% lesions that are individually non-significant can combine more often than thought to hemodynamic significance in hyperemic conditions.

19.
J Relig Health ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565834

RESUMO

This systematic review and meta-analysis aimed to evaluate the effectiveness of spiritually based interventions on blood pressure (BP) among adults. A systematic search was performed using the PubMed, Scopus, and Cochrane databases to identify studies evaluating spiritual interventions, including meditation, transcendental meditation, mindfulness meditation, and yoga, for high BP among adults up to January 1, 2022. The inclusion criteria were (a) randomized controlled trials (RCTs), (b) studies in English or Persian, (c) studies conducted among adults (≥ 18 years), and (d) studies reporting systolic or diastolic BP. Given the high heterogeneity of these studies, a random effect model was used to calculate the effect sizes for the RCTs. In total, the systematic review included 24 studies and the meta-analysis included 23 studies. As some of studies reported two or more outcome measurements, separate estimates of each outcome were extracted for that study (24 datasets). Fifteen trials reported the mean (SD) systolic blood pressure (SBP), and 13 trials reported the mean (SD) diastolic blood pressure (DBP). In addition, 13 studies reported means (SDs) and six trials reported mean changes in DBP. A significant decrease was found in systolic BP following intervention ((WMD (weighted mean difference) = - 7.63 [- 9.61 to - 5.65; P < 0.001]). We observed significant heterogeneity among the studies (I2 = 96.9; P < 0.001). A significant decrease was observed in DBP following the interventions (WMD = - 4.75 [- 6.45 to - 3.05; P < 0.001]). Spiritually based interventions including meditation and yoga had beneficial effects in reducing both SBP and DBP. Reducing BP can be expected to reduce the risk of cardiovascular diseases.

20.
Small ; : e2310032, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566533

RESUMO

Wearable pressure sensors have attracted great interest due to their potential applications in healthcare monitoring and human-machine interaction. However, it is still a critical challenge to simultaneously achieve high sensitivity, low detection limit, fast response, and outstanding breathability for wearable electronics due to the difficulty in constructing microstructure on a porous substrate. Inspired by the spinosum microstructure of human skin for highly-sensitive tactile perception, a biomimetic flexible pressure sensor is designed and fabricated by assembling MXene-based sensing electrode and MXene-based interdigitated electrode. The product biomimetic sensor exhibits good flexibility and suitable air permeability (165.6 mm s-1), comparable to the typical air permeable garments. Benefiting from the two-stage amplification effect of the bionic intermittent structure, the product bionic sensor exhibits an ultrahigh sensitivity (1368.9 kPa-1), ultrafast response (20 ms), low detection limit (1 Pa), and high-linearity response (R2 = 0.997) across the entire sensing range. Moreover, the pressure sensor can detect a wide range of human motion in real-time through intimate skin contact, providing essential data for biomedical monitoring and personal medical diagnosis. This principle lays a foundation for the development of human skin-like high-sensitivity, fast-response tactile sensors.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...